Common causes
- Flow too low to trigger the burner. A clogged aerator, low-flow fixture or dirty inlet filter can keep the unit from firing.
- Scale in the heat exchanger. Albuquerque's hard water coats the inside, cutting heat transfer.
- Not enough gas. An undersized gas line can't feed the burner when other appliances run.
- Ignition failure codes. Many units show an ignition error, such as code 11 on Rinnai models, when the burner won't light: often gas supply, venting or the igniter.
- Cold-water sandwich. A brief burst of cold between uses is a normal trait of many tankless units.
- Undersized unit for winter inlet temperatures.
What you can check
- Clean faucet aerators and showerheads.
- Note any error code on the display.
- See if it only happens when the furnace, dryer or stove is running too.
Then call with the code. See tankless repair and descaling.
Questions we hear
What does Rinnai error code 11 mean?
It's an ignition failure code. Common causes are gas supply, venting or the igniter. Have it checked if it repeats.
Why is my tankless hot in summer but not in winter?
Inlet water is much colder in winter, and an undersized unit can't raise it enough at higher flow.
How often should a tankless be descaled?
In hard-water areas, regularly. Check the manufacturer's guidance.