Licensed NM contractorPrice before work startsGas, electric & tanklessOld heater hauled away
Call (505) 479-3940

Home › Guides › Pilot Won't Stay Lit

Troubleshooting

Water Heater Pilot Won't Stay Lit

(505) 479-3940

The pilot lights, then goes out when you let go. Here's what usually causes it.

Gas control valve and burner access panel on a tank water heater
Gas control valve and burner access panel on a tank water heater

Common causes

  • Worn thermocouple or thermopile. This sensor tells the gas valve the pilot is lit. When it weakens, the valve shuts off. The most common cause.
  • Dirty or weak pilot flame. A small or yellow flame doesn't heat the sensor enough.
  • Tripped flammable vapor sensor on newer heaters, sometimes from dust or lint.
  • Drafts or venting problems that blow the pilot out or starve it of air.
  • Failing gas control valve.

What you can safely check

  • Follow the relighting steps on the heater's label exactly.
  • Make sure nothing stored nearby is blocking airflow, and that no gasoline or solvents are near the heater.

If it still won't stay lit, call. If you ever smell gas, leave and call your gas company or 911 from outside.

Technician connecting a new gas tank water heater
Technician connecting a new gas tank water heater

See water heater repairs.

Questions we hear

How much does a thermocouple replacement cost?

It's one of the less expensive water heater repairs. We'll price it before we do it.

Why does the pilot go out on windy days?

Wind can create downdrafts in the vent. A venting check usually finds the cause.

Is it safe to keep relighting it?

A few attempts following the label is fine. Repeated failures mean a part needs replacing.

No hot water? Leaking tank?

Call now and talk to someone who can tell you what it is and when we can be there.

Call (505) 479-3940
Call (505) 479-3940